KKT Kraus KLC 126 N Chiller (2003)KKT Kraus
Kaltwassersatz
KKT Kraus KLC 126 N Chiller (2003)
KKT Kraus
Kaltwassersatz
Rok výroby
2003
Stav
Použitý
Umístění
Menslage 

Základní údaje
- Označení stroje:
- KKT Kraus KLC 126 N Chiller (2003)
- Výrobce:
- KKT Kraus
- Model:
- Kaltwassersatz
- Rok výroby:
- 2003
- Stav:
- použitý
Cena a lokalita
- Místo prodejce:
- Mühlenhorst 8, 49637 Menslage, Německo

Zavolat
Podrobnosti nabídky
- ID inzerátu:
- A229-83526
- Referenční číslo:
- DE-BLO-KKT-2003-00001
- Aktualizace:
- naposledy dne 15.10.2026
Popis
Overview
This KKT Kraus KLC 126 N is an air-cooled industrial chiller, built in 2003. It runs on refrigerant R407C, with the condenser fans on top and the control cabinet built into one end face.
The unit is dismantled and stored, ready for loading.
Technical data
- Manufacturer: KKT Kraus
- Model: KLC 126 N
- Year of manufacture: 2003
Godjz Sp Nhjpfx Anzjuh
- Machine type: air-cooled chiller
- Refrigerant: R407C, max. filling weight 43.5 kg
- Max. operating pressure: 28 bar
- Power supply: 400 V, 3 phases, 50 Hz
- Max. power input: 64 kW
- Max. current consumption: 118 A
- Main fuse: 160 A
- CE marked
Equipment
- Air-cooled condenser with axial fans on top of the housing
- Integrated control cabinet with digital temperature controller, indicator lamps, selector switch and main switch
- Pipe connections on the end face opposite the control cabinet
- Enclosed steel housing
Condition
Used chiller from 2003, dismantled and stored.
Availability
Available immediately. Location: Germany.
This KKT Kraus KLC 126 N is an air-cooled industrial chiller, built in 2003. It runs on refrigerant R407C, with the condenser fans on top and the control cabinet built into one end face.
The unit is dismantled and stored, ready for loading.
Technical data
- Manufacturer: KKT Kraus
- Model: KLC 126 N
- Year of manufacture: 2003
Godjz Sp Nhjpfx Anzjuh
- Machine type: air-cooled chiller
- Refrigerant: R407C, max. filling weight 43.5 kg
- Max. operating pressure: 28 bar
- Power supply: 400 V, 3 phases, 50 Hz
- Max. power input: 64 kW
- Max. current consumption: 118 A
- Main fuse: 160 A
- CE marked
Equipment
- Air-cooled condenser with axial fans on top of the housing
- Integrated control cabinet with digital temperature controller, indicator lamps, selector switch and main switch
- Pipe connections on the end face opposite the control cabinet
- Enclosed steel housing
Condition
Used chiller from 2003, dismantled and stored.
Availability
Available immediately. Location: Germany.
Tyto inzeráty by vás také mohly zajímat.
Úspěšně
Vaše zpráva byla odeslána.
Malý inzerát
Menslage
617 km
KKT KrausKaltwassersatz
Váš inzerát byl úspěšně smazán
Došlo k chybě










